Fault Codes:
Liebherr General E027
Solution:
Switch to the emergency control speed adjustment switch S71 and S72 as well as emergency operation working pumps Y50
Fault Description:
Insufficient hydraulic power
Fault Cause:
There is a fault in the LR cable during the power control output stage of the hydraulic pump