Fault Codes:
Sany The SY245/265H is equipped with a Mitsubishi Heavy Indu 102
Solution:
The MHI diagnostic software shows the code 3DO0F6
Fault Description:
There is an abnormal short circuit in the jet 1 circuit
Fault Location:
Fuel injector
Sany The SY245/265H is equipped with a Mitsubishi Heavy Indu 102
The MHI diagnostic software shows the code 3DO0F6
There is an abnormal short circuit in the jet 1 circuit
Fuel injector