Hyundai HX220 NL EPFC 153(105-3)

Fault Description:

Intake Manifold 1 Temperature Sensor Circuit - Voltage Above Normal, or Shorted to High Source. High signal voltage detected; Intake manifold 1 temperature sensor circuit - voltage higher than the normal value, or short-circuited to the high power supply. A high signal voltage was detected in the intake manifold air temperature circuit.

Fault Location:

Possible white smoke. Fan will stay ON if controlled by ECM. No protection for intake manifold air temperature; White smoke may appear. The ECM control fan will keep rotating. No intake manifold air temperature protection