Fault Codes:
Hyundai HX220 NL EPFC 164-6
Solution:
1. Check for open circuits or short circuits in the CR-47(#85)-CN-54(#9) line 2. Check for open circuit or short circuit in the CR-47(#30,#86)- fuse box (#28) circuit
Fault Description:
(Testing conditions (When the working cut-off relay is turned on For 10 seconds, the driving current of the working cut-off relay is greater than 6.5A (Conditions for termination (When the working cut-off relay is turned on For 3 seconds, the driving current of the working cut-off relay is ≤6.5A
Fault Location:
1. Control function -(Wheeled excavator) The hydraulic pilot pressure cut-off of the accessory fails in the driving mode