Fault Codes:
Hyundai HX220 NL EPFC 169-6
Solution:
1. Check for open circuits or short circuits in the CN-507(#1)-CN-505(#83) lines 2. Check for open circuits or short circuits in the CN-507(#2)-CN-505(#44) lines
Fault Description:
(Testing conditions (When the attached combined solenoid valve is open) For 10 seconds, the driving current of the attached combined solenoid valve is greater than 6.5A (Conditions for termination (When the attached combined solenoid valve is open) For 3 seconds, the driving current of the attached combined solenoid valve is ≤6.5A
Fault Location:
1. Control function - Optional accessory flow control combined operation failed (Energy-saving crushing mode, grinding mode