Fault Codes:
Hyundai HX220 NL EPFC 189-6
Solution:
1. Check for open circuits or short circuits in the CN-243(#2)-CN-54(#26) lines 2. Check for open circuits or short circuits in the CN-243(#1)-CN-54(#03) lines
Fault Description:
(Testing conditions For 10 seconds, the attachment flow EPPR 2 driving current is greater than 1.0A (Conditions for termination For 3 seconds, the driving current of the attachment flow EPPR 2 is ≤1.0A
Fault Location:
1. Control function - The optional accessory flow control has failed